Endpoints

GET /my-EPC/

Summary: Get Device Info Description: Tags: my-EPC Operation ID: get_device_info_fake_device__get

Responses:

  • 200: Successful Response


GET /my-EPC/EPC/

Summary: Get Component Info Description: Return metadata. Tags: my-EPC, my-EPC Operation ID: get_component_info_fake_device_EPC__get

Responses:

  • 200: Successful Response


PUT /my-EPC/EPC/power-on

Summary: Power On Description: Power on the sensor.

Returns:

None Tags: my-EPC, my-EPC Operation ID: power_on_fake_device_EPC_power_on_put

Responses:

  • 200: Successful Response


PUT /my-EPC/EPC/power-off

Summary: Power Off Description: Power off the sensor.

Returns:

None Tags: my-EPC, my-EPC Operation ID: power_off_fake_device_EPC_power_off_put

Responses:

  • 200: Successful Response


GET /my-EPC/EPC/read-pressure

Summary: Read Pressure Description: Read the current pressure from the sensor and return it in the specified units.

Parameters:

units : str, optional The units in which to return the pressure (default is bar).

Returns:

float The current pressure in the specified units. Tags: my-EPC, my-EPC Operation ID: read_pressure_fake_device_EPC_read_pressure_get

Query Parameters:

  • units (string, optional, default = bar)

Responses:

  • 200: Successful Response

  • 422: Validation Error


GET /my-EPC/EPC/get-pressure

Summary: Get Pressure Description: Get the current system pressure in bar.

Returns:

float The current pressure in bar. Tags: my-EPC, my-EPC Operation ID: get_pressure_fake_device_EPC_get_pressure_get

Responses:

  • 200: Successful Response


PUT /my-EPC/EPC/set-pressure

Summary: Set Pressure Setpoint Description: Set the controlled pressure to the instrument; default unit is bar.

Parameters:

pressure : str The desired pressure to set.

Returns:

bool True if the pressure setpoint was set successfully. Tags: my-EPC, my-EPC Operation ID: set_pressure_setpoint_fake_device_EPC_set_pressure_put

Query Parameters:

  • pressure (string, required, default = ``)

Responses:

  • 200: Successful Response

  • 422: Validation Error


PUT /my-EPC/EPC/stop

Summary: Stop Description: Stop the pressure controller by setting pressure to 0 bar.

Returns:

bool True if the pressure controller was stopped successfully. Tags: my-EPC, my-EPC Operation ID: stop_fake_device_EPC_stop_put

Responses:

  • 200: Successful Response


Components

ComponentInfo (object)

Description: Metadata associated with flowchem components.

Properties:

  • name: string (default: ``)

  • parent_device: string (default: ``)

  • type: string (default: ``)

  • owl_subclass_of: array (default: ['http://purl.obolibrary.org/obo/OBI_0000968'])


DeviceInfo (object)

Description: Metadata associated with hardware devices.

Properties:

  • manufacturer: string (default: ``)

  • model: string (default: ``)

  • version: string (default: ``)

  • serial_number: object (default: unknown)

  • components: object (default: {})

  • backend: string (default: flowchem v. 1.0.0a3)

  • authors: array (default: [])

  • additional_info: object (default: {})


HTTPValidationError (object)

Properties:

  • detail: array


ValidationError (object)

Required: loc, msg, type

Properties:

  • loc: array

  • msg: string

  • type: string