Endpoints
GET /my-EPC/
Summary: Get Device Info
Description:
Tags: my-EPC
Operation ID: get_device_info_fake_device__get
Responses:
200: Successful Response
GET /my-EPC/EPC/
Summary: Get Component Info
Description: Return metadata.
Tags: my-EPC, my-EPC
Operation ID: get_component_info_fake_device_EPC__get
Responses:
200: Successful Response
PUT /my-EPC/EPC/power-on
Summary: Power On Description: Power on the sensor.
Returns:
None
Tags: my-EPC, my-EPC
Operation ID: power_on_fake_device_EPC_power_on_put
Responses:
200: Successful Response
PUT /my-EPC/EPC/power-off
Summary: Power Off Description: Power off the sensor.
Returns:
None
Tags: my-EPC, my-EPC
Operation ID: power_off_fake_device_EPC_power_off_put
Responses:
200: Successful Response
GET /my-EPC/EPC/read-pressure
Summary: Read Pressure Description: Read the current pressure from the sensor and return it in the specified units.
Parameters:
units : str, optional The units in which to return the pressure (default is bar).
Returns:
float
The current pressure in the specified units.
Tags: my-EPC, my-EPC
Operation ID: read_pressure_fake_device_EPC_read_pressure_get
Query Parameters:
units(string, optional, default =bar)
Responses:
200: Successful Response422: Validation Error
GET /my-EPC/EPC/get-pressure
Summary: Get Pressure Description: Get the current system pressure in bar.
Returns:
float
The current pressure in bar.
Tags: my-EPC, my-EPC
Operation ID: get_pressure_fake_device_EPC_get_pressure_get
Responses:
200: Successful Response
PUT /my-EPC/EPC/set-pressure
Summary: Set Pressure Setpoint Description: Set the controlled pressure to the instrument; default unit is bar.
Parameters:
pressure : str The desired pressure to set.
Returns:
bool
True if the pressure setpoint was set successfully.
Tags: my-EPC, my-EPC
Operation ID: set_pressure_setpoint_fake_device_EPC_set_pressure_put
Query Parameters:
pressure(string, required, default = ``)
Responses:
200: Successful Response422: Validation Error
PUT /my-EPC/EPC/stop
Summary: Stop Description: Stop the pressure controller by setting pressure to 0 bar.
Returns:
bool
True if the pressure controller was stopped successfully.
Tags: my-EPC, my-EPC
Operation ID: stop_fake_device_EPC_stop_put
Responses:
200: Successful Response
Components
ComponentInfo (object)
Description: Metadata associated with flowchem components.
Properties:
name: string (default: ``)parent_device: string (default: ``)type: string (default: ``)owl_subclass_of: array (default:['http://purl.obolibrary.org/obo/OBI_0000968'])
DeviceInfo (object)
Description: Metadata associated with hardware devices.
Properties:
manufacturer: string (default: ``)model: string (default: ``)version: string (default: ``)serial_number: object (default:unknown)components: object (default:{})backend: string (default:flowchem v. 1.0.0a3)authors: array (default:[])additional_info: object (default:{})
HTTPValidationError (object)
Properties:
detail: array
ValidationError (object)
Required: loc, msg, type
Properties:
loc: arraymsg: stringtype: string